Thermal variations should be taken into account due to seasonal changes, during which a uniform heating of the structure can occur, and in another season, cooling of the structure.
Hence, if thermal loads are to be introduced, carry out the following steps:
- Create two additional live load loadcases in Job > Loads > Additional loadcases > live load. Call them +30 and –30 for example.
- Select Load > Introduce loads on bars and activate all the bars of the structure. To do so, click in the topmost corner and open a capture window.
- In the dialogue box that opens, select +30 for the loadcase and click on the Dt icon. Type a value of 30 in the value box.
- Select Load > Introduce loads on bars and activate all the bars of the structure. To do so, click in the topmost corner and open a capture window.
- In the dialogue box that opens, select -30 for the loadcase and click on the Dt icon. Type a value of -30 in the value box.
Once the structure has been analysed, click on Analysis > Force diagrams > Deformed shape and the user can see how the frame dilates for +30 loadcase, and contracts for the –30 loadcase. |